Troubleshooting Checklist
Troubleshooting 4-5
No Local
Management
Password screen.
Autobaud is enabled, but
the baud rate has not yet
been detected.
Press ENTER (RETURN) (may take up to
four times).
Terminal setup is not
correct.
Refer to the SmartSwitch Series 2E253,
2H252, 2H253, and 2H258 Local
Management User’s Guide for proper setup
procedures.
Improper console cable
pinouts.
Refer to Appendix A for proper console port
pinouts.
Corrupt firmware image,
or hardware fault.
If possible, attempt to download the image to
the 2H258-17R again. Refer to Section B for
instructions to clear NVRAM.
Cannot navigate
beyond Password
screen.
Improper Community
Names Table.
1. Refer to the SmartSwitch Series 2E253,
2H252, 2H253, and 2H258 Local
Management User’s Guide for Community
Names Table setup.
2. If you have forgotten the Community
Names, refer to Appendix B for
instructions on how to set the mode switch
to reset the Community Names to their
default values.
Table 4-2 Troubleshooting Checklist (Continued)
Problem Possible Cause Recommended Action