IGMP Configuration Command Set
Setting IGMP Query Interval and Response Time
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 10-5
10.2.2.2 set igmp query-interval
Use this command to set the IGMP query interval as defined in RFC 2236, Section 8.2.
set igmp query-interval intervaltime
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the IGMP query interval to 60 seconds:
10.2.2.3 show igmp response-time
Use this command to display the IGMP response time setting.
show igmp response-time
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
intervaltime Specifies the frequency of host-query frame
transmissions. Valid values are from 30 to 600 seconds.
Matrix>set igmp query-interval 60